服務(wù)熱線
13210558111
通風(fēng)設(shè)備壓縮機(jī)正常范圍:壓縮機(jī)在夏季制冷狀態(tài)下,排氣溫度比較高,不可用手觸摸。制冷系統(tǒng)的排氣溫度不超過(guò)125℃左右。故障:排氣溫度超高原因,是壓縮機(jī)的吸氣溫度超高,或是冷凝溫度超高所造成,必須引起注意。上海風(fēng)管加工排氣溫度過(guò)低,手摸排氣管不燙手,這說(shuō)明吸氣溫度特別低,壓縮機(jī)可能濕行程運(yùn)行或系統(tǒng)制冷劑特少情況下運(yùn)行。壓縮機(jī)濕行程運(yùn)行容易損壞閥結(jié)構(gòu);制冷劑特少情況運(yùn)行,會(huì)影響電動(dòng)機(jī)的繞組散熱,加速絕緣材料的老化。
Normal range of ventilation equipment compressor: When the compressor is in the cooling state in summer, the exhaust temperature is relatively high and cannot be touched by hand. The exhaust temperature of the refrigeration system shall not exceed around 125 ℃. Fault: The reason for the high exhaust temperature is due to the high suction temperature of the compressor or the high condensation temperature, which must be taken seriously. The exhaust temperature of Shanghai air duct processing is too low, and touching the exhaust pipe does not make it too hot. This indicates that the suction temperature is particularly low, and the compressor may run wet or with very little refrigerant in the system. The wet stroke operation of the compressor can easily damage the valve structure; Operating with very little refrigerant can affect the heat dissipation of the motor winding and accelerate the aging of insulation materials.
通風(fēng)設(shè)備壓縮機(jī)殼體溫度正常范圍:上機(jī)殼受吸入蒸氣的影響,溫度比較低,處在微熱或稍涼范圍,估計(jì)在30℃左右,在吸氣管的周?chē)植繖C(jī)殼表面有結(jié)露水的可能。下機(jī)殼內(nèi)電動(dòng)機(jī)的發(fā)熱量和被冷凍油帶出的摩擦熱量,上海風(fēng)管加工廠主要由蒸氣帶出機(jī)殼。故障:機(jī)殼表面溫度超過(guò)正常范圍,主要是制冷系統(tǒng)的吸氣溫度過(guò)高。過(guò)高的熱蒸氣迸入壓縮機(jī),吸收機(jī)殼內(nèi)熱量后,使蒸氣的溫度更高,從而使機(jī)殼的溫度上升。機(jī)殼表團(tuán)溫度低于正常范圍,其原因是吸氣溫度太低。它對(duì)冷凍油和電動(dòng)機(jī)繞組的冷卻都有利,但制冷量有所下降。
The normal temperature range of the ventilation equipment compressor housing: The upper casing is affected by the inhalation of steam, and the temperature is relatively low, in a slightly hot or slightly cool range, estimated to be around 30 ℃. There is a possibility of condensation on the surface of the local casing around the suction pipe. The heat generated by the electric motor inside the lower casing and the frictional heat carried out by the refrigeration oil are mainly carried out of the casing by steam at the Shanghai air duct processing plant. Fault: The surface temperature of the casing exceeds the normal range, mainly due to the high suction temperature of the refrigeration system. Excessive hot steam rushes into the compressor, absorbing the heat inside the casing, causing the temperature of the steam to rise, thereby increasing the temperature of the casing. The temperature of the casing cluster is below the normal range, due to the low suction temperature. It is beneficial for the cooling of refrigeration oil and motor windings, but the cooling capacity has decreased.
排煙管道送風(fēng)口設(shè)置在實(shí)際需要降溫的地方,風(fēng)口設(shè)計(jì)風(fēng)量即使以其要降溫地方所需的送風(fēng)量,風(fēng)口規(guī)格可根據(jù)風(fēng)量與風(fēng)口風(fēng)速來(lái)確定,螺旋風(fēng)管廠家送風(fēng)口材質(zhì)可采用塑料或鋁合金等制品,出風(fēng)口風(fēng)咀形式可根據(jù)實(shí)際情況采用多種形式,選擇錦煜空調(diào)專(zhuān)用風(fēng)咀,風(fēng)口喉部平均流速控制在3-6m/s,(采用4-5m/s的流速)。送風(fēng)管的規(guī)格一般采用假定流速法設(shè)計(jì),共板風(fēng)管主風(fēng)管保持在8-10m/s,支風(fēng)管6-8m/s,*末端風(fēng)管保持4-6m/s,所設(shè)計(jì)的風(fēng)管總體上要求既經(jīng)濟(jì)又能達(dá)到*低的風(fēng)阻和噪聲,使錦煜冷風(fēng)機(jī)的送風(fēng)量盡量達(dá)到*大值,風(fēng)管彎曲半徑一般不小于風(fēng)管直徑的兩倍,以減少管通風(fēng)阻力,送風(fēng)管道的長(zhǎng)度應(yīng)根據(jù)不同型號(hào)的錦煜空調(diào)風(fēng)壓不同的特點(diǎn)進(jìn)行設(shè)計(jì)。所設(shè)計(jì)的排煙管道盡量取直,避免不必要的拐彎和分支管,上海通風(fēng)管道以減少管道局部阻力,從平面布置和經(jīng)濟(jì)角度上考慮,能不用風(fēng)管的地方就不用風(fēng)管,必須使用風(fēng)管的地方盡量把風(fēng)管設(shè)計(jì)短些,較長(zhǎng)管道根據(jù)風(fēng)量設(shè)計(jì)成多段不同規(guī)格的風(fēng)管,采用變徑管連接,變徑管的設(shè)置不宜過(guò)多,一風(fēng)管廠家般整根不超過(guò)四個(gè),變徑管長(zhǎng)由“>2(D-d)”來(lái)確定,送風(fēng)管道與冷風(fēng)機(jī)主機(jī)出風(fēng)口連接處應(yīng)密封好;室外管道過(guò)長(zhǎng)宜設(shè)計(jì)保溫,室內(nèi)管道一般不須保溫
The smoke exhaust duct air supply outlet is set in the actual place that needs to be cooled. The designed air volume of the air outlet can be determined based on the air volume and the air speed of the outlet. The material of the spiral air duct manufacturer's air supply outlet can be plastic or aluminum alloy, and the form of the air outlet nozzle can be in various forms according to the actual situation. It is recommended to choose a dedicated air outlet for Jinyu air conditioning, with an average flow rate at the throat of the air outlet controlled at 3-6m/s, (It is recommended to use a flow rate of 4-5m/s). The specifications of the air supply duct are generally designed using the assumed flow rate method. The main air duct of the common plate air duct is kept at 8-10m/s, the branch air duct is kept at 6-8m/s, and the end air duct is kept at 4-6m/s. The designed air duct is generally required to be both economical and achieve low wind resistance and noise, so that the air supply volume of the Jinyu cold air fan can reach the maximum value possible. The bending radius of the air duct is generally not less than twice the diameter of the air duct to reduce the ventilation resistance of the duct, The length of the air supply duct should be designed according to the different characteristics of the air pressure of different models of Jinyu air conditioners. The designed smoke exhaust pipes should be as straight as possible to avoid unnecessary bends and branch pipes. Shanghai ventilation pipes should be designed to reduce local resistance of the pipes. From the perspective of layout and economy, air ducts should not be used in areas where air ducts are not necessary. Air ducts should be designed as short as possible in areas where air ducts must be used. Long pipes should be designed into multiple sections of different specifications of air ducts according to the air volume, and variable diameter pipes should be used for connection. The number of variable diameter pipes should not be too many, A manufacturer of air ducts generally does not exceed four in a single piece, and the length of variable diameter pipes is determined by ">2 (D-d)". The connection between the supply air duct and the outlet of the cold air fan should be sealed properly; Outdoor pipelines that are too long should be designed with insulation, while indoor pipelines generally do not require insulation
上一篇:飯店油煙機(jī)排煙罩的制作要求
下一篇:廚房排煙設(shè)備排煙管道結(jié)構(gòu)要點(diǎn)